Fire Detection & Alarm Systems

Fire Detection & Alarm Systems Contractor

 - fire alarm contractors in Indonesia - SNI fire alarm contractor in Indonesia - Indonesian fire alarm contractors - Selangor fire alarm contractor Indonesia - Singapore fire alarm contractors - Nigeria fire alarm system contractor in Indonesia - Yemen fire alarm system contractors - Japanese fire alarm contractor Indonesia - Bangkok fire alarm contractors Indonesia - Thailand fire alarm contractor in Indonesia - total fire alarm installation contractors - efficient fire alarm installation contractor - Bandung fire alarm installation contractors - Jakarta fire alarm installation - upgraded fire alarm system installation - fire detection and alarm system contractors in Indonesia - local fire detection and alarm system contractor in Indonesia - IEEE fire alarm system contractors in Indonesia - IEC fire alarm system contractor in Indonesia - API fire larm contractors in Indonesia - NFPA fire alarm contractor in Indonesia -

Omazaki Design & Build  is a designer and contractor company for the installation of a fire detection and alarm systems located in Tangerang Selatan Banten, not too far from the capital city of Jakarta Indonesia. We design and install fire alarm systems that use cable or wireless, and both conventional and addressable systems. As contractors, we design, present and install sophisticated detectors and fire alarm systems equipment that can be adapted to the needs and requirements of industry and commercial buildings in Indonesia. We have highly qualified engineers with years of experience in this field.

———————————————

Overview of Fire Detection and Alarm

Fire detection and alarm system is part of fire protection system. It is primarily a life safety system meant for detecting the fire at its early stages then alarming the surroundings.

Main Components of Fire Detection and Alarm Systems
  • Initiating Devices
  • Detectors (smoke, flame, heat and gas)
  • Manual pull station (manual call point/MCP)
  • Water flow switch
  • Valve temper switch
  • Fire Control Alarm Panels
  • Notification Appliances
  • Buzzers
  • Bells
  • Horns
  • Strobes
System Options

 - Fire Detection Alarm Systems - NFPA 2020 latest - fire alarm systems contractor - FCA - fire alarm systems contractors - MCFA - fire alarm installation contractor - gas detector - fire alarm installation contractors - Jakarta fire alarm contractor in Indonesia - KL - fire alarm contractor Indonesia - fire alarm contractors - USA fire alarm contractors in Indonesia - Canada fire alarm contractor Indonesia - Europe fire alarm contractors - Asia Fire Detection Alarm Systems - Malaysia fire alarm installation contractor - fire alarm installation contractors - best fire alarm contractor in Indonesia - certified fire alarm contractor Indonesia - local fire alarm contractors - international fire alarm contractors in Indonesia - excellent fire alarm contractor Indonesia - professional fire alarm contractors - standard Fire Detection Alarm Systems - Swiss fire alarm contractors - Finland fire alarm contractor - Nokia fire alarm contractors - Sweden fire alarm contractors - Eaton fire alarm contractor - Honeywell fire alarm contractors - Notifier fire alarm contractors - new fire alarm contractors - revised NFPA fire alarm contractor - Japan fire alarm contractor - fire alarm systems contractor - fire alarm systems contractor Indonesia - fire alarm systems contractors Bali - fire alarm systems contractor Jakarta Pusat - design fire alarm systems contractors international - plan fire alarm system installation - develop fire alarm system installation - revision fire alarm system installation Indonesia jaya - fire alarm systems design - fire alarm system installation Indonesia maju - fire alarm system installation -

  • Conventional systems
  • Addressable systems
  • Analogue addressable systems
  • Wireless systems

Options for addressable systems

  • Semi addressable system
  • Full addressable system

The detectors can be smoke detector, flame detector, heat detector, and/or gas detector.

———————————————

Scope of Works (SOW)

Design Basis and Detailed Design
  • Site survey and assessment
  • Selecting the category of protection and coverage
  • Mapping, zoning and grouping (configuration)
  • Prepare and propose system’s options
  • Prepare specification of main components and support materials
  • Software simulation
  • Mechanical and electrical layout
  • Single-line diagram
  • Bill of material (BoM) and cost estimation
Procurement & Installation
  • Materials supply
    • Fire detector (heat, flame, smoke, gas or multi sensor detector)
    • Fire control alarm panels and support devices
    • Manual Call Point (MCP), indicator lamp and fire bell
    • Cable, terminator and cable support materials
    • Emergency battery or UPS
    • Other requested features
  • Installation
  • Testing, commissioning and start-up
Other services
  • Project documents (as-built drawing, data-sheet, etc)
  • Legal certification from Kemenaker
  • Personnel hands-on training
  • Troubleshooting assistance

———————————————

For further explations of our solutions and services related to fire detection and alarm systems installation design planning and contractors services in Indonesia, please contact us by filling out the form in contact.